| Parameter | Value |
|---|---|
| Temp control | |
| Cooling capacity 540 Vdc model¹ | 3 kW |
| COP cooling 540 Vdc model¹ | 2 |
| Cooling capacity 360 Vdc model¹ | 3 kW |
| COP cooling 360 Vdc model¹ | 2 |
| Cooling capacity 24 Vdc model¹ | 2,8 kW |
| COP cooling 24 Vdc model¹ | 2,5 |
| Heating capacity 540 Vdc model² | 3,5 kW |
| COP heating 540 Vdc model² | 3 |
| Heating capacity 360 Vdc model² | 3,5 kW |
| COP heating 360 Vdc model² | 3 |
| Heating capacity 24 Vdc model² | 3,3 kW |
| COP heating 24 Vdc model² | 3,5 |
| Heating capacity electric 540 Vdc model | 1,3 kW |
| Voltage for heating capacity electric 540 Vdc model | 790 Vdc |
| Heating capacity electric 360 Vdc model | 1,5 kW |
| Voltage for heating capacity electric 360 Vdc model | 400 Vdc |
| Heating capacity electric 24 Vdc model | N/A |
| Voltage for heating capacity electric 24 Vdc model | N/A |
| Max airflow evaporator (free blowing) | 820 m³/h |
| Refrigerant | R134A non-flammable. A1 refrigerant, allowed to be used in EU for mobile applications, cooling batteries and equipment. R1234yf or R513a on request |
| Max ambient temperature³ | 50 °C |
| Min ambient temperature | -15 °C |
| Max indoor temperature | 40 °C |
| Min indoor temperature | -15 °C |
| Electrical | |
| Primary voltage range 540 Vdc model | 400-790±5 Vdc |
| Primary voltage range 360 Vdc model | 240-420±5 Vdc |
| Primary voltage range 24 Vdc model | 20-32 Vdc |
| Secondary voltage range | 20-32 Vdc |
| Control system | Remote on/ off, HMI panel, Modbus R485, or self-controlled |
| Power consumption 540 Vdc model | 0-4,5 kW |
| Power consumption 360 Vdc model | 0-4,5 kW |
| Power consumption 24 Vdc model | 0-2 kW |
| Power consumption secondary voltage | 0,65 kW (not needed for 24 Vdc model) |
| Degree of protection(components to be protected from water and dust | IP65 |
| Mechanical | |
| Size | 825 x 860 x 355 mm (L x W x H) |
| Weight | 72 kg |
| Material | Aluminium |
| Colour | Powder-coated RAL 7035 |
| Sound level indoor (1 m distance non-resonating mounting) | 72 dB(A) @ 80% ventilator speed |
| Sound level outdoor (1 m distance non-resonating mounting) | 68 dB(A) @ 30 °C |
¹ Tested in 30 °C 50% RH indoor / 35 °C outdoor. Cooling duty varies on climatic conditions and altitude, consult DC Airco for specific applications.
² Tested in 10 °C indoor / 10 °C outdoor.
³ Simulating peak ambient temperature conditions during the day.