This monoblock air conditioner is designed for vehicles and offers efficient heating and cooling capabilities, operating between -20 °C and 45 °C through its internal heat pump circuit and e-heaters. All the parts necessary for the unit are packed in a single cabinet, and the unit is fully operational when you unpack it. The cabinet is made of aluminium sheet metal, 1,5 mm thick, and has a grey RAL 7035 powder coating. All fastening components are stainless steel.

Configuration:

Monoblock

Type:

Air to Air

Serie:

DC9000

Cooling Capacity:

0,53 kW

Heating Capacity:

0,5–3,5 kW

Heating Options:

Cooling Only, Electric Heating, Heatpump, Heatpump + Electric Heating

Primary Voltage:

540/360/24 Vdc

Secondairy Voltage:

24 Vdc

Attachements:

Under development, files will be available soon.

Technical Overview

ParameterValue
Temp control
Cooling capacity 540 Vdc model¹3 kW
COP cooling 540 Vdc model¹2
Cooling capacity 360 Vdc model¹3 kW
COP cooling 360 Vdc model¹2
Cooling capacity 24 Vdc model¹2,8 kW
COP cooling 24 Vdc model¹2,5
Heating capacity 540 Vdc model²3,5 kW
COP heating 540 Vdc model²3
Heating capacity 360 Vdc model²3,5 kW
COP heating 360 Vdc model²3
Heating capacity 24 Vdc model²3,3 kW
COP heating 24 Vdc model²3,5
Heating capacity electric 540 Vdc model1,3 kW
Voltage for heating capacity electric 540 Vdc model790 Vdc
Heating capacity electric 360 Vdc model1,5 kW
Voltage for heating capacity electric 360 Vdc model400 Vdc
Heating capacity electric 24 Vdc modelN/A
Voltage for heating capacity electric 24 Vdc modelN/A
Max airflow evaporator (free blowing)820 m³/h
RefrigerantR134A non-flammable. A1 refrigerant, allowed to be used in EU for mobile applications, cooling batteries and equipment. R1234yf or R513a on request
Max ambient temperature³50 °C
Min ambient temperature-15 °C
Max indoor temperature40 °C
Min indoor temperature-15 °C
Electrical
Primary voltage range 540 Vdc model400-790±5 Vdc
Primary voltage range 360 Vdc model240-420±5 Vdc
Primary voltage range 24 Vdc model20-32 Vdc
Secondary voltage range20-32 Vdc
Control systemRemote on/ off, HMI panel, Modbus R485, or self-controlled
Power consumption 540 Vdc model0-4,5 kW
Power consumption 360 Vdc model0-4,5 kW
Power consumption 24 Vdc model0-2 kW
Power consumption secondary voltage0,65 kW (not needed for 24 Vdc model)
Degree of protection(components to be protected from water and dustIP65
Mechanical
Size825 x 860 x 355 mm (L x W x H)
Weight72 kg
MaterialAluminium
ColourPowder-coated RAL 7035
Sound level indoor (1 m distance non-resonating mounting)72 dB(A) @ 80% ventilator speed
Sound level outdoor (1 m distance non-resonating mounting)68 dB(A) @ 30 °C

¹ Tested in 30 °C 50% RH indoor / 35 °C outdoor. Cooling duty varies on climatic conditions and altitude, consult DC Airco for specific applications.