DC 25000 400V Roof mounted Air conditioner
Description
This rooftop mounted air conditioner available in 400V is designed for cooling down autonomous, driverless, self-driving shuttles, buses, electric vehicles, and trucks running in a high outdoor temperature up to 52 degrees Celsius. There are no expensive converters needed to run since it completely 400V.
Air-Conditioning - Cooling for batteries and people:
- Driverless vehicles
- Autonomous shuttles
- Self-driving buses
- Electric trucks
To run a battery power source such as:
- 400V
- 850V
Description
This rooftop mounted air conditioner available in 400V is designed for cooling down autonomous, driverless, self-driving shuttles, buses, electric vehicles, and trucks running in a high outdoor temperature up to 52 degrees Celsius. There are no expensive converters needed to run since it completely 400V.
Air-Conditioning - Cooling for batteries and people:
- Driverless vehicles
- Autonomous shuttles
- Self-driving buses
- Electric trucks
To run a battery power source such as:
- 400V
- 850V
Features
The robust housing is made of powder coated stainless steel (optional zinc plated steel) The premium PLC controller shows all settings and fault codes on a display.
The very efficient air conditioner combines a very low consumption with a high cooling output. The cooling duty of this unit is much higher than a normal air conditioner and there is no power surge during startup (soft start).
The optional fresh air can be preheated or precooled before entering the cab. The fresh air intake is a small module with G3 filter that can be placed inside the vehicle on a location with easy access. Preferably the air room of the engine. For a dirty/dusty environment the unit can be delivered with an overpressure system according to ISO 10263.
The units are designed to meet:
EN 14813-1-2006 Air conditioning for driving Cabs
EN 2004/108/EC EN 50121-3-2:2006 EN 55011:2007/A2 EN 61000-4-2/6
EMC EN 61373 vibration and shock resistance for Rolling Stock.
EN 45545-HL 3 for cable and optional for all other non-metal parts.
EN 2006/42/EC Machine Safety regulations
Cooling Capacity 30/35 BTU/h /watt | 25000 / 7000 |
---|---|
Airflow in the cab M³/h | 500 / 1300 ( 1300 when in heating mode) |
Optional Fresh air intake minimum maximum M³/h | 60-300 |
Power Consumption Watt | 2500 air conditioner, 3500 heater |
Voltage | 400 V |
Max allowable temperature Celsius | 52 C |
cab noise dB(A) fan low/high | 40-65 |
Outdoor noise dB(A) | 78 upwards |
Size indoor air in outlet ceiling plate with controls | 900 W x 600 L x 3 H |
Size outdoor unit | 900 W x 1670L x 280 H |
Size of the optional fresh Air filter unit/overpressure | 407 W x 205 D x 506 H |
Refrigerant | R134A (nonflammable) |
Weight | max 200 kg |
Cooling duty varies on climatic conditions and altitude- consult factory for specific applications.