DC Airco type 8500 is developed as the DC 8000 but to make a more universal split unit it became the 8500.
It’s introduced in 2004 and used in the same applications as the DC 9000 if there is a sloped roof or a height maximum.
           
 

8500 ROOSTER

outdoor unit

 

 

DC 8500 12 volt

DC 8500 24 volt

Cooling capacity

2500 Watt – 8525 BTU

2750 Watt – 9370 BTU

Power consumption

600 Watt 50 A

600 Watt 25 A

Size mm (outdoor unit)

Size inches

600 W x 230D  x 850H

23,6 W x 9,0D x 33,5 H

600 W x 230D  x 850H

23,6W x 9,0D x 33,5 H

Size mm (indoor unit)

Size iches

575 H x 670 W x 150 D

22,64 H x 26,4 W x 5,9 D

575 H x 670 W x 150 D

22,64 H x 26,4 W x 5,9 D

Weight

56 kg / 124 lbs

56 kg / 124 lbs

Max. outdoor ambient

45 ºC / 113 ºF

45 ºC / 113 ºF

Low voltage settings

12 VDC = 10,5 volt

24 VDC = 21,5 volt

Restart settings (If there was a low voltage the unit will restart at)

12 VDC = 12,6 volt

24 VDC = 25,2 volt

High pressure switch

24 bar

24 bar

Low pressure switch

2 bar

2 bar

Safety switches

Max. temperature compressor and motor

Max. temperature compressor and motor

Coolant/ refrigerant

R134a

R134a